Testsealabs FOB Fecal Occult Blood Rapid Test
(Fece)
1. Product information sheet:
Product Name |
FOB rapid test |
Specimen |
feces |
Storage |
4-30°C |
Specification |
25pcs/box |
Shelf life |
24 months |
OEM |
Available |
2. Intended use:
Many diseases may result in hidden blood in the feces. This is known as fecal occult blood (FOB), human occult blood, or human hemoglobin. In the early stages, gastrointestinal problems such as colon cancer, ulcers, polyps, colitis, diverticulitis, and fissures may not show any visible symptoms, only occult blood. Traditional guaiac based methods of occult blood testing lack sensitivity and specificity, and also require diet restrictions prior to testing. Fecal occult blood tests are used as a screening tool for detecting lower gastrointestinal (GI) bleeding that may be related to iron deficiency anemia, peptic ulcer, ulcerative colitis, polyps, and colorectal cancer. The FOB Test Device is recommended for use by health professionals in routine physical examinations and in monitoring for GI bleeding in patients in hospitals or in physicians' offices. The Fecal Occult Blood Test is a simple, visual qualitative test that detects human hemoglobin from blood in fecal. The test is based on immunochromatography and can give a result within 5 minutes.
3. Test procedure:
Allow the test, specimen and/or controls to reach room temperature 15-30ºC (59-86ºF) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2. Place the test device on a clean and level surface.
3. Holding the sample collection tube upright, carefully take off the tip of collection tube, transfer 3 drops (approximately 100μl) to the specimen well(S) of the test device, then start the timer. See illustration below.
Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
Notes:
Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of specimen to the specimen well.
4. INTERPRETATION OF RESULTS
Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.
Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.
Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
FAQs:
Q: What are your price?
A: Our price are subject to change depending on supply and other market factors. We will send you an updated price list after your company contact us for further information.
Q: Do you have a minimum order quantity?
A : Yes, require all international orders to have an ongoing minimum order quantity. If you are looking to resell but in much smaller quantities, we recommend you check our our website.
Q: Can you supply the relevant documentation?
A: Yes, we can provide most documentation including certificates and other export documents where required.
Q: Can you make OEM or ODM service?
A: Yes. We can accept OEM service. Meanwhile it's also welcome to choose our ODM products.